PIN DECAL not found

$
0
0

Dear All,

 

I am newbie to Pads. While creating a new part I get an error.  Please advise. Attached Image

 

 

Akshay


Custom Query to report wire Part # and MC # in a single column

$
0
0

We have a requirement for our wire table to display the wire part# or the multicore part# within in single column. Currently the wire table displays in two different columns.

 

I have created a custom Query and not working, here is what I have written

Custom query.JPG

Custom query out.JPG

Notice the wire part # appears but not the Multicore part #.

 

Any suggestion or help would be greatly appreciated.

Thank you

DX Designer discreet comp. value

$
0
0

The discreet components symbol that I downloaded from PartQuest is showing the value in farads instead of uf eg. 0.0000047 farad instead of 4.7uf. The same thing with the resistor value 5600 Ohm instead of 5.6K. Is there anyway to change this globally in DataBook or is there any setting I should use when importing from PartQuest?

Thank you in advance for your support.

 

Restricting modify access to the VeSys database

$
0
0

Hello,

 

     I am currently trying to restrict modify access to our VeSys database to all but 6 users. What would be the suggested method for doing this? I have tried creating a new user under Tools > Edit Users, but I can't seem to log on to the new account I create. Any insight would be much appreciated.

 

Thank you,

     Bob M.

How to controll the decimal (trailing)units in PADS ??

$
0
0

Hi everyone,

 

Let me explain any one how to control the decimal place in PADS Layout.For example (100.00mil or 2.540mm) maintain in allegro (mil or MM ) but i worked across the pads l never seen like that even i worked lot of boards some time decimal units varying

i need to maintain same decimal (Trailing )units in all the board should be same

 

Unit.png

DECIMAL POINT IN DXDATABOOK VALUE FIELD

$
0
0

How can i display in dxdatabook a value like 8,192MHz instead of 8M192Hz? Here are my settings (VALUE field):

 

1.jpg2.jpg3.jpg

Thanks

Problem with .drl after loading in gerbv

$
0
0

Hi,

I have a problem after loading gerber files and drils file in gerbv. After changing file format to Trailing (zero_supression), inch (units) and 2 (digits) holes from drill file are shifted. Below is the image. In CAM in device properities for NC Drills setings are:

Output Type-ASCII,

Units-English,

#of Digits Leading-2 Trailing 4

Zero Suppress-Trailing

Coordintes-Absolute

 

What's the problem. My Pads Layout version is 9.4.

 

gerbv.png

HKP File will not import into Library at mirror site

$
0
0

Has anyone an idea on how to fix the following problem, we have created a part in our library and exported it to a hkp file.

We have then sent this file to our mirror site (in china) for them to import into there copy of the library.

(for adding a few parts or cells this (used to be) a better way than keep sending complete libraries).

Now when they try to import parts (or cells) they get errors where usually it says unknown keyword - attached is file for latest parts showing error.

 

This method used to work find in 7.9.1 version of the software - but seems to now be a problem when we are all using VX 1.1 (Expedition Flow)

 

Because the hkp files are encrypted I cannot double check to see if the keyword in present or not.

 

Any ideas on how to fix this or what to check etc.

Thanks


Query to Replace Terminal Part# with Termianl BOM ID

$
0
0

I want to replace the Term PN with BOM_ID's due to our business process.

I would like to know if a query can be written to pull the generated BOM_ID  for the Terminal in a separate custom column.

Your help is greatly appreciated.

TERMBOMID.jpg

embedded or Oracle database

$
0
0

How to decide wich database to select Oracle database or embedded database for Capital 2014

 

  • We are big company - many Capital users
  • Pros and cons of each type of database.
  • Embedded database limitations
  • Any attached documentations would be more then welcome

PARTQUEST no longer functional

$
0
0

PartQuest was a useful tool when first used in VX1.1. Was able to download, unzip footprints from Digikey and open in Pads layout and add to libraries. Then I upgraded to VX1.2 a few months back. Have only recently discovered that PartQuest is no longer functional. Can still download parts and unzip from Digikey, but cannot open using "Tools: Import PartQuest Parts" in Pads Layout. Error message "Windows cannot access specific device, path or file. You may not have appropriate permissions to access item".

    Put in an SR(#2846049879) on Support Net. While waiting for resolution from Mentor, decided to post here to see if anyone else has had this issue and have recommendations. I already tried release switcher back to VX1.1(did not fix issue) and uninstalling PartQuest from system and reinstalling PartQuest(still did not fix issue). Not sure what else to do at this point. Worse case scenario, I would contemplate uninstalling all Mentor products and then reinstalling, but concerned of other issues arising from this "brute force" method.

     Any feedback would be greatly aprreciated.

Thanks

Tom S.

Senior PCB Designer

NJ

Inline image 1

Symbol library import error

$
0
0

Hello,

 

I have below error while importing symbol library, can anyone help me to understand the issue.

Import Symbol Library Error. The file Symbol_library.xml is not a valid Symbol Library file. Attribute "baseid" must be declared for element type "propertiedtext".

 

 

Thanks,

Jagadhees

Impedance discontinuity of differential vias.

$
0
0

Why extra stubs in differential vias have more capacitive discontinuity as compared to inductive discontinuity.

Thanks

 

How do you add a new line in a property field?

$
0
0

I have created a new User Property which I have defined as having a limit of 60 characters and 3 lines.  If the first line is only 20 characters how do I get it to move to the next line?

Setting a PCB heat flux

$
0
0

Hi! I'm currently using FloTHERM XT as part of my master thesis in thermal simulation. I've successfully imported and set all powers individually on components after filtering the smaller ones out in the FloEDA Bridge, however, I can't seem to find any option to set a board-wide general heat flux that would compensate for the filtered out components. Any idea how I can do this?


PARTQUEST Problems

$
0
0

Still not resolved. After upgrading to VX1.2, part quest no longer functional. Uninstalled and reinstalled PartQuest did not help. Uninstalled VX1.1 and VX1.2, clean boot then reinstalled VX1.2 only. Import part quest from tools menu linked directly to website, downloaded but cannot open *.pqz file. Installed recommended Partquest integration tool for Designer and original error(see image) returns. Ran Mentor's install program to verify installation and see these errors(see partquest error doc). This problem is also on websupport under ServiceRequest #  2846049879.

Any ideas or recommendations? This tool was helpful initially when it was first working in VX1.1.

Query for Column with Wire and Outer MC name

$
0
0

Hello,Need help with query.

Below is query which gives out names for wire/MC ID in the same column. But for Multi core, only the outer MC ID should be visible.

Query.jpg

In below table within Red Box only MC1 should be visible.

NAME COLUMN.jpg

Want to know IF conditions can be created within query?

Best Regards,Arjun

Newbie help: General setup of model in FloTHERM XT

$
0
0

Hi!

 

I'm currently trying to set up a model in FloTHERM XT where I have a PCB ready for import through .idf format. Everything goes great, but I'm getting weird values when comparing to measurements. How should I set up the model if I am to analyse a PCB with heat sources inside an air-tight enclosure? I'm interested in some surface goals on the components to match against my measurements. The simulation is meant to be rough to see the possibility of using it in early design, so the enclosure is to be a simple box, with a PCB inside.

 

EDIT: In this enclosure, I also have a heat pad that engulfs the components on the back of the PCB, which is then connected to an aluminum back plate. How do I model this without errors in solving as the meshing complains at this moment. I've done this as a cuboid with a set thermal conductivity now. Is there a way to do this with a TIM instead?

line sim via 3d modeling

$
0
0

I modeled a differential via in line-sim using 3D via modeling

 

 

while viewing 3D model it manually assigns ports as +1,-1,+2 and -2

Are these ports correct why it is not assigned as 1,2,3,4 like in board-sim.

xDx Designer script to automatically propagate block name as Cluster property to components

$
0
0

The add_cluster scripts add cluster properties to all components of a hierarchical design.

The script uses the block "Name" of a hierarchical block symbol and puts that name to all componens underneath.

It works  recursive, so lower level hierarchy blocks get e.g. Cluster=Memory/Upper. Therefore also the resulting planning groups in xPCB are hierarchical.

 

 

 

How to use:

 

'''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''

'

' AutoAdd_cluster Addin: Propagate blockname attributes through design hierarchy as cluster property to components

'Automation and Scripting

' Prerequisites: 

'    - All hierarchy block symbols should have a name associated (which gets the cluster prop) otherwise the instance name (e.g. $1I6) gets assigned

' Setup:

'    - copy the 3 files add_custer_core.vbs, add_cluster_gui.vbs and add_cluster.bmp into any of your WDIR directories.

'   - add the path to the add_cluster_gui.vbs in the xDX Designer startup file entry (Setup>Settings>Run on Startup,  or scripts.ini)

' Usage:

'    - Make sure every hierarchy block symbol has a name assigned, if not the script will use the UID instead and warn the user in the output window

'    - Invoke command with toolbar icon or Edit > AutoAdd Cluster Properties

'

'   (c) 2016 Mentor Graphics Corp.

'    No warranties expressed or implied. (Use at you own risk.)

'   Direct comments or questions to Gerhard_Busch@mentor.com

'      based on prop_reuse scripts by michal_smolinski@mentor.com

'

'     Verified on MGC releases: VX1, should run with later releases

'     Version 1.0: 18.02.2016

'

'''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''